Product ΔT N2 (27°C) ΔT N2 (50°C) ΔT Vacuum (27°C) ΔT Vacuum (50°C) Qmax 27°C (watts) Imax 27°C (amps) Vmax 27°C (volts) Base Ceramic Width(mm) Base Ceramic Length(mm) Top Ceramic Width(mm) Top Ceramic Length(mm) Module Height(mm)
XLT2420-01LS 59.0 67.0 0.0 0.0 52 5.6 14.4 40.01 44.70 40.01 40.01 3.86
LCC12-8-01LS 66.0 74.0 0.0 0.0 71 7.4 14.7 40.01 40.01 40.01 40.01 3.94
XLT6-4-01LS 65.0 73.0 0.0 0.0 20 3.7 8.2 23.5 27.99 23.5 23.5 3.33
LCC12-10-01LS 62.0 70.0 0.0 0.0 85 8.9 14.7 40 40 40 40 3.84
XLT3-4-01LS 65.0 73.0 0.0 0.0 9 3.7 3.6 16 20.5 16 16 3.33
XLT2416-04AC 56.0 63.5 0.0 0.0 33.9 14.7 3.6 25.40 28.70 25.40 25.40 3.81
LCC12-8-16LS 66.0 74.0 0.0 0.0 71 7.4 14.7 40.01 40.01 40.01 40.01 3.94
XLT2422-01LS 66.0 74.0 0.0 0.0 36 3.7 14.7 30.0 34.0 30.0 30.0 3.33
LCC12-10-16LS 62.0 70.0 0.0 0.0 85 8.9 14.7 40 40 40 40 3.84
XLT3-8-01LS 64.0 72.0 0.0 0.0 16.89 7.4 3.49 20 24.43 20 20 3.55
XLT2418-04AC 56.5 64.0 0.0 0.0 127 13.9 14.1 40.01 44.70 39.57 39.57 2.34
XLT2393-01LS 58.0 67.0 0.0 0.0 187 13.4 21.4 40 40 40 38.02 2.41
XLT2423-31AC 58.0 66.0 0.0 0.0 95 19 7.7 36.40 54.41 35.84 50.24 3.05

  1. XLT2420-01LS

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  2. LCC12-8-01LS

    Used in PCR processing and semiconductor test equipment ROHS EU compliant Superior nickel diffusion barriers on elements High strength for rugged environments RTV sealing available Lapped for superior height control Designed for temperature cycling applications Rated operating temperature of 130C Modules with matched AC Resistance available Lapped modules allow for multiple module applications Aluminum Oxide ceramics
    Learn More

  3. XLT6-4-01LS

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  4. LCC12-10-01LS

    Used in PCR processing and semiconductor test equipment ROHS EU compliant Superior nickel diffusion barriers on elements High strength for rugged environments RTV sealing available Lapped for superior height control Designed for temperature cycling applications Rated operating temperature of 130C Modules with matched AC Resistance available Lapped modules allow for multiple module applications Aluminum Oxide ceramics
    Learn More

  5. XLT3-4-01LS

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  6. XLT2416-04AC

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  7. LCC12-8-16LS

    Used in PCR processing and semiconductor test equipment ROHS EU compliant Superior nickel diffusion barriers on elements High strength for rugged environments RTV sealing available Lapped for superior height control Designed for temperature cycling applications Rated operating temperature of 130C Modules with matched AC Resistance available Lapped modules allow for multiple module applications Aluminum Oxide ceramics
    Learn More

  8. XLT2422-01LS

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  9. LCC12-10-16LS

    Used in PCR processing and semiconductor test equipment ROHS EU compliant Superior nickel diffusion barriers on elements High strength for rugged environments RTV sealing available Lapped for superior height control Designed for temperature cycling applications Rated operating temperature of 130C Modules with matched AC Resistance available Lapped modules allow for multiple module applications Aluminum Oxide ceramics
    Learn More

  10. XLT3-8-01LS

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  11. XLT2418-04AC

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  12. XLT2393-01LS

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More

  13. XLT2423-31AC

    Used in PCR processing and semiconductor test equipment Designed for thermal cycling applications Capable of rapid heating and cooling rates Proven high reliability (data available upon request) Porched configuration for enhanced leadwire strength Modules with matched AC Resistance available Lapping option for superior height control Lapped modules allow for multiple module applications Rated operating temperature of 125C Aluminum Oxide ceramics
    Learn More